Ultrasonic water flowmeter
- Size Range: DN40~DN600
- Pulse output: Reed switch
- Protection: IP68
- Accuracy: R160~R400
- Temperature: T50, T90, T130
WORKING PRINCIPLES:
The sound wave that flows in the direction of the stream moves faster than the one that flows against the stream.
The transit times Tab (Transit time of ultrasonic waves from sensor A to sensor B) and Tba (from sensor B to A) are measured continuously. The time difference (Tba - Tab) is directly proportional to the mean flow velocity (Vm) of the liquid. The flow rate is a result of the velocity multiplied by the cross section area of the flow tube size.
CHARACTERITICS:
No moving parts permitting the most reliable and longer term life; lowest pressure loss;
Battery life: ≥4years; possible to keep the external Battery bag for easy to exchange;
AMR ready for RS485, M-BUS...;
Digital Display:
Main Technical Data: ISO 4064 Class B
MAX PERMISSION ERROR:
FOR CLASS I:
From Q1 inclusive up to but excluding Q2 is ± 1%; From Q2 inclusive up to and including Q4 is ± 3%; FOR CLASS II:
From Q1 inclusive up to but excluding Q2 is ± 2%; From Q2 inclusive up to and including Q4 is ± 5%;
Suggest to install the ULW water meter at U15 D5 (Straight pipe before the water meter at
15D, after the water meter at 5D);
Suggest to install the same size of the FILTER before the water meter;
Only for Horizontal installation;
Technical Data
Item |
GL-UL Series Ultrasonic Water Meter |
Pipe Diameter |
DN15-DN40mm Single Channel Smal sizel Ultrasonic Water Meter DN50-DN150mm Dual Channel Bulk Ultrasonic Water Meter DN200-DN600mm Dual Channel Bulk Ultrasonic Water Meter |
Measurement Medium |
Water, Sewage, Sea Water (or customized for other liquid). Full Pipe liquid |
Temperature |
0.1~30℃ |
Working Environment |
Temperature:-10-45 ℃; Humidity:≤100% (RH)) |
Working Pressure |
1.6Mpa (2.5 MPa optional) |
Upstream Sensitivity |
U3 |
Downstream Sensitivity |
D0 |
Electromagnetic Compatibility Class |
E2 |
Communication Interface |
RS485/USART/Infrared |
Output |
Two way OCT pulse output/TTL pulse output/One way 4-20mA output |
Power Supply |
Built in Lithium battery (3.6, 19AhV) VDC8~36V power supply |
Protection Class |
IP68, can work 2 meters under water |
Digital Display |
.Multi line 9 digital accumulative flow 4 digital display for instantaneous flow |
Data Storage |
EEPROM/FLASH automatically record the accumulative flow of last 512 days |
Measurement Cycle |
Measuring:1times/second; Verification:4times/second |
Power Consumption |
DN15-DN150mm battery life more than 10 years DN200-DN600mm battery life more than 6 years |
Performance of Electrodes